- MPN / P/N
- 740-083294
- Модель производителя
- JNP-100G-AOCBO-30M
- Заводской номер
- 740-083294
- Скорость линии — по документации
- 4 x 25 Gigabit Ethernet
- Поддержка breakout — с ограничениями платформы
- Yes
- Формфактор
- QSFP28 to SFP28
- Тип изделия
- AOC
- Разъём
- None
- Наличие мониторинга
- Yes
- Цифровой оптический мониторинг
- Yes
- QSFP28(SFF-8665), SFP28(SFF-8402) MSA / Тип кабеля / волокна
- MMF
- QSFP28(SFF-8665), SFP28(SFF-8402) MSA / Digital Diagnostic Monitoring
- Tx Power Rx Power Bias Current Case Temperature Power Supply Voltage
- QSFP28(SFF-8665), SFP28(SFF-8402) MSA / Дальность / длина — с условиями профиля
- 30 m
- QSFP28(SFF-8665), SFP28(SFF-8402) MSA / MSA compliance (SFF, for e.g. SFF-8665)
- QSFP28 MSA, SFF-8665, “QSFP28 28 Gb/s4X Pluggable Transceiver Solution (QSFP28)”, Rev 1.9, June 29, 2015 SFP28 MSA, SFF-8402, “Specification for SFP28 1X 28 Gb/s Pluggable Transceiver Solution (SFP28) ”, Rev 1.1, Sep 13, 2014
- QSFP28(SFF-8665), SFP28(SFF-8402) MSA / Максимальное энергопотребление
- QSFP28 end: 3.5 W; SFP28 end: 1 W
- QSFP28(SFF-8665), SFP28(SFF-8402) MSA / Диапазон рабочей температуры
- 0° C to 70° C
- QSFP28(SFF-8665), SFP28(SFF-8402) MSA / Optic Type (Commercial Vs Service Provider Grade)
- OM3
- QSFP28(SFF-8665), SFP28(SFF-8402) MSA / Скорость сигнализации на полосу
- 25.78125Gbd +/- 100ppm
- QSFP28(SFF-8665), SFP28(SFF-8402) MSA / Температура хранения
- –40° C to 85° C
- QSFP28(SFF-8665), SFP28(SFF-8402) MSA / Typical Weight & Dimensions
- Dimensions | QSFP28 | SFP28 Height | 8.5 mm | 8.5 mm Width | 18.35 mm | 13.4 mm Depth | 72.4 mm | 56.5 mm
- Ограничения подбора по документации
- Reach, rate, form factor and breakout support apply only to the listed standard/mode, fiber grade and platform/port configuration. Keep source qualifiers for FEC, attenuation, transmit/receive limits, temperature, active/passive operation and cable ends. Check Juniper HCT for the exact host, interface module, port mode, Junos release, required QSA adapter and qualifications before ordering. Do not infer universal interoperability or combine power/temperature/reach across model profiles. Optical link budgets are not calculated or inferred. Parallel fiber/core/modal-bandwidth/distance values retain the same source column order; correlate matching columns instead of applying the largest distance to every fiber.
- Пояснение встроенного кабеля
- Connector=None в HCT — поле метаданных цельного DAC/AOC, а не отсутствие концов кабеля. Типы окончаний и breakout проверяются по Form Factor и профилю производителя.
- Как читать параллельные значения
- Значения через | в строках волокна, полосы и дальности сопоставляются по одинаковым позициям в порядке таблицы производителя. Максимальная дальность не относится ко всем типам волокна.