- MPN / P/N
- 740-068639
- Ishlab chiqaruvchi modeli
- JNP-SFP-25G-SR
- Zavod raqami
- 740-068639
- Liniya tezligi — hujjat bo‘yicha
- 25 Gigabit Ethernet
- Breakout — platforma cheklovlari bilan
- No
- Format
- SFP28
- Mahsulot turi
- Optical Transceiver
- Ulagich
- Duplex LC PC/UPC
- Monitoring mavjudligi
- Yes
- Raqamli optik monitoring
- Yes
- 25GBASE-SR / Kabel / tola turi
- MMF
- 25GBASE-SR / Yadro / qoplama o‘lchami
- 50/125 µm
- 25GBASE-SR / Digital Diagnostic Monitoring
- transceiver temperature transceiver supply voltage TX bias current TX output power RX received optical power
- 25GBASE-SR / Masofa / uzunlik — profil shartlari bilan
- 70 m | 100 m
- 25GBASE-SR / Effective modal bandwidth
- 2000 MHz x km | 4700 MHz x km
- 25GBASE-SR / Tola sinfi
- OM3 | OM4
- 25GBASE-SR / MSA compliance (SFF, for e.g. SFF-8665)
- SFF-8402
- 25GBASE-SR / Maksimal quvvat sarfi
- 1.5 W
- 25GBASE-SR / Ishlash harorati oralig‘i
- 0° C to 70° C
- 25GBASE-SR / Optic Type (Commercial Vs Service Provider Grade)
- Commercial
- 25GBASE-SR / Qabul kanali to‘lqin uzunligi oralig‘i
- 840 to 860 nm
- 25GBASE-SR / Har kanal maksimal kirish quvvati
- 2.4 dBm
- 25GBASE-SR / Har kanal minimal kirish quvvati
- -10.3 dBm
- 25GBASE-SR / Har bir kanal signal tezligi
- 25.78125 GBd ± 100 ppm
- 25GBASE-SR / Saqlash harorati
- –40° C to 85° C
- 25GBASE-SR / Stressed receiver sensitivity (OMA) each lane (maximum)
- -5.2 dBm
- 25GBASE-SR / Transmitter RMS spectral width (maximum)
- 0.6 nm
- 25GBASE-SR / Transmitter fibers
- 1
- 25GBASE-SR / Har kanal maksimal chiqish quvvati
- 2.4 dBm
- 25GBASE-SR / Har kanal minimal chiqish quvvati
- -8.4 dBm
- 25GBASE-SR / Uzatgich to‘lqin uzunligi oralig‘i
- 840 nm to 860 nm
- 25GBASE-SR / Typical Weight & Dimensions
- Weight: 0.15 kg Height: 8.55 mm Width: 13.55 mm Depth: 57.5 mm
- Hujjatdagi tanlash cheklovlari
- Reach, rate, form factor and breakout support apply only to the listed standard/mode, fiber grade and platform/port configuration. Keep source qualifiers for FEC, attenuation, transmit/receive limits, temperature, active/passive operation and cable ends. Check Juniper HCT for the exact host, interface module, port mode, Junos release, required QSA adapter and qualifications before ordering. Do not infer universal interoperability or combine power/temperature/reach across model profiles. Optical link budgets are not calculated or inferred. Parallel fiber/core/modal-bandwidth/distance values retain the same source column order; correlate matching columns instead of applying the largest distance to every fiber.
- Parallel qiymatlarni o‘qish
- Tola, polosa va masofaning | bilan ajratilgan qiymatlari ishlab chiqaruvchi jadvali ustun tartibida bir xil pozitsiyaga mos keladi. Eng uzoq masofa har bir tolaga tegishli emas.