- MPN / P/N
- 740-073130
- Ishlab chiqaruvchi modeli
- JNP-100G-AOCBO-1M
- Zavod raqami
- 740-073130
- Liniya tezligi — hujjat bo‘yicha
- 4 x 25 Gigabit Ethernet
- Breakout — platforma cheklovlari bilan
- Yes
- Format
- QSFP28 to SFP28
- Mahsulot turi
- AOC
- Ulagich
- None
- Monitoring mavjudligi
- Yes
- Raqamli optik monitoring
- Yes
- QSFP28(SFF-8665), SFP28(SFF-8402) MSA / Kabel / tola turi
- MMF
- QSFP28(SFF-8665), SFP28(SFF-8402) MSA / Digital Diagnostic Monitoring
- Tx Power Rx Power Bias Current Case Temperature Power Supply Voltage
- QSFP28(SFF-8665), SFP28(SFF-8402) MSA / Masofa / uzunlik — profil shartlari bilan
- 1 m
- QSFP28(SFF-8665), SFP28(SFF-8402) MSA / MSA compliance (SFF, for e.g. SFF-8665)
- QSFP28 MSA, SFF-8665, “QSFP28 28 Gb/s4X Pluggable Transceiver Solution (QSFP28)”, Rev 1.9, June 29, 2015 SFP28 MSA, SFF-8402, “Specification for SFP28 1X 28 Gb/s Pluggable Transceiver Solution (SFP28) ”, Rev 1.1, Sep 13, 2014
- QSFP28(SFF-8665), SFP28(SFF-8402) MSA / Maksimal quvvat sarfi
- QSFP28 end: 3.5 W; SFP28 end: 1 W
- QSFP28(SFF-8665), SFP28(SFF-8402) MSA / Ishlash harorati oralig‘i
- 0° C to 70° C
- QSFP28(SFF-8665), SFP28(SFF-8402) MSA / Optic Type (Commercial Vs Service Provider Grade)
- OM3
- QSFP28(SFF-8665), SFP28(SFF-8402) MSA / Har bir kanal signal tezligi
- 25.78125Gbd +/- 100ppm
- QSFP28(SFF-8665), SFP28(SFF-8402) MSA / Saqlash harorati
- –40° C to 85° C
- QSFP28(SFF-8665), SFP28(SFF-8402) MSA / Typical Weight & Dimensions
- Dimensions | QSFP28 | SFP28 Height | 8.5 mm | 8.5 mm Width | 18.35 mm | 13.4 mm Depth | 72.4 mm | 56.5 mm
- Hujjatdagi tanlash cheklovlari
- Reach, rate, form factor and breakout support apply only to the listed standard/mode, fiber grade and platform/port configuration. Keep source qualifiers for FEC, attenuation, transmit/receive limits, temperature, active/passive operation and cable ends. Check Juniper HCT for the exact host, interface module, port mode, Junos release, required QSA adapter and qualifications before ordering. Do not infer universal interoperability or combine power/temperature/reach across model profiles. Optical link budgets are not calculated or inferred. Parallel fiber/core/modal-bandwidth/distance values retain the same source column order; correlate matching columns instead of applying the largest distance to every fiber.
- O‘rnatilgan kabel metama’lumoti izohi
- HCT Connector=None yaxlit DAC/AOC metama’lumoti, kabel uchlari yo‘q degani emas. Uch formati va breakout aniq ishlab chiqaruvchi profilidan tekshiriladi.
- Parallel qiymatlarni o‘qish
- Tola, polosa va masofaning | bilan ajratilgan qiymatlari ishlab chiqaruvchi jadvali ustun tartibida bir xil pozitsiyaga mos keladi. Eng uzoq masofa har bir tolaga tegishli emas.