- MPN / P/N
- 4C57A16216
- Ma’lumotnoma holati
- Ma’lumotnoma: kod Legacy/EOL yoki Withdrawn hujjatlarida keltirilgan. O‘rnatilgan uskuna almashtirishini tanlash uchun; aniq joriy hayot sikli va mavjudlik tekshiriladi.
- Ishlab chiqaruvchi modeli
- SD530 RAID
- Adapter turi
- RAID controller
- Ichki / tashqi portlar
- Internal
- Konfiguratsiya kodi — alohida part-raqami emas
- AUYK
- Format
- Custom
- Kontroller / chip
- LSI SAS3408
- Host interfeysi
- PCIe 3.0 x8
- Port interfeysi
- 12 Gb SAS
- Kontroller portlari soni
- 6
- Port ulagichlari
- 2x SlimSAS x4
- Disk interfeyslari
- SAS, SATA
- Disk turlari
- HDD, SSD, SED
- Disklarni issiq almashtirish
- Yes
- To‘g‘ridan-to‘g‘ri ulanish — fizik disk chegarasi
- 6
- Qo‘llanadigan ekspander bilan disk chegarasi
- 63
- Mantiqiy disk chegarasi
- 32
- RAID darajalari
- 0, 1, 10, 5, 50
- JBOD rejimi
- Yes
- Kontroller keshi
- None
- Kesh himoyasi — to‘plam alohida tekshiriladi
- No
- Performance Accelerator (FastPath)
- Yes
- SSD Caching (CacheCade Pro 2.0)
- No
- SED qo‘llashi — shartlarni ko‘ring
- Yes (SafeStore)
- Remote management - Controller FW update (XCC/BMC) (see Note 5)
- Yes
- Remote management - Inventory (XCC/BMC) (see Note 5)
- Yes
- Remote management - RAID setup (XCC/BMC) (see Note 5)
- Yes
- Ishlab chiqaruvchi hujjatidagi hayot sikli
- Withdrawn (live Lenovo Press reference, checked 2026-10-19)
- Hujjatdagi sotuvdan olish sanasi
- 2024-12-26
- Hujjatdagi tanlash cheklovlari
- Use only the approved ThinkSystem server, slot/riser, backplane and correct cable/firmware configuration. Port count, direct physical-drive limit and expander-qualified drive limit are separate source fields. HBA passthrough is not hardware RAID. Flash/supercap support does not imply an optional module is supplied; consult the exact option guide. NVMe U.3 Tri-Mode x1 and NVMe-only U.2 x4 configurations are different and not simultaneous universal support; feature codes/CH5Z enablement and host cabling must be verified for RAID 940. Planned U.2 support stays planned, not a delivered feature. SED support on HBAs is host-software pass-through, not a bundled encryption/key-management service. Remote management exclusions and blade drive-count limits in sourceQualifications apply. Withdrawn hardware is recorded for installed-equipment reference/replacement, not current production or stock availability.
- Ishlab chiqaruvchi izohlari — tanlash uchun shart
- Note 1: RAID 730-8i 1GB is available world-wide except USA and Canada
Note 2: SAS HBAs support SEDs by host software passing SED commands through the HBA to the drives.
Note 3: SN550 blade 4i adapters are limited to two drives and RAID 0/1; SN850 has four drives and applicable RAID modes depend on the exact adapter.
Note 5: SR635/SR655/SR645/SR665 with second-generation AMD EPYC (Rome) processors do not support remote management.