- MPN / P/N
- 740-058734
- Manufacturer model
- QSFP-100GBASE-SR4
- Part Number
- 740-058734
- Speed
- 4 x 25 Gigabit Ethernet, 100 Gigabit Ethernet
- Breakout Capable
- Yes
- Breakout cables
- MTP-4LC-M1M, MTP-4LC-M3M, MTP-4LC-M5M, MTP-4LC-M10M can be used as break-out cables
- Form Factor
- QSFP28
- Product Type
- Optical Transceiver
- Connector
- MPO-12 PC/UPC
- Monitoring Available
- Yes
- Digital Optical Monitoring
- Yes
- IEEE 802.3-2018 / Cable type
- MMF
- IEEE 802.3-2018 / Core size/cladding
- 50/125 µm
- IEEE 802.3-2018 / Diagnostic support
- Yes
- IEEE 802.3-2018 / Distance
- 70 m | 100 m
- IEEE 802.3-2018 / Effective modal bandwidth
- 2000 MHz x km | 4700 MHz x km
- IEEE 802.3-2018 / Fiber grade
- OM3 | OM4
- IEEE 802.3-2018 / Maximum Power consumption (W)
- 3.5 W
- IEEE 802.3-2018 / Operating Temperature (range)
- 0° C to 70° C
- IEEE 802.3-2018 / Receive lane wavelengths (range)
- 840 nm through 860 nm
- IEEE 802.3-2018 / Receiver input power, each lane (maximum)
- 2.4 dBm
- IEEE 802.3-2018 / Receiver input power, each lane (minimum)
- –10.3 dBm
- IEEE 802.3-2018 / Signaling rate, each lane
- 25.78125 GBd +/- 100 ppm
- IEEE 802.3-2018 / Standards compliance (Ethernet/OTN Standard, for e.g. 100GBASE-LR4)
- 100GBASE-SR4 (Clause 95)
- IEEE 802.3-2018 / Storage temperature
- –40° C to 85° C
- IEEE 802.3-2018 / Transmitter output power, each lane (maximum)
- 2.4 dBm
- IEEE 802.3-2018 / Transmitter output power, each lane (minimum)
- –8.4 dBm
- IEEE 802.3-2018 / Transmitter wavelengths (range)
- 840 nm through 860 nm
- Documented selection limits
- Reach, rate, form factor and breakout support apply only to the listed standard/mode, fiber grade and platform/port configuration. Keep source qualifiers for FEC, attenuation, transmit/receive limits, temperature, active/passive operation and cable ends. Check Juniper HCT for the exact host, interface module, port mode, Junos release, required QSA adapter and qualifications before ordering. Do not infer universal interoperability or combine power/temperature/reach across model profiles. Optical link budgets are not calculated or inferred. Parallel fiber/core/modal-bandwidth/distance values retain the same source column order; correlate matching columns instead of applying the largest distance to every fiber.
- Reading parallel values
- Pipe-separated fiber, bandwidth and reach values correspond by position in the original manufacturer column order. The longest reach does not apply to every fiber type.