- MPN / P/N
- 740-073145
- Manufacturer model
- JNP-100G-AOCBO-10M
- Part Number
- 740-073145
- Speed
- 4 x 25 Gigabit Ethernet
- Breakout Capable
- Yes
- Form Factor
- QSFP28 to SFP28
- Product Type
- AOC
- Connector
- None
- Monitoring Available
- Yes
- Digital Optical Monitoring
- Yes
- QSFP28(SFF-8665), SFP28(SFF-8402) MSA / Cable type
- MMF
- QSFP28(SFF-8665), SFP28(SFF-8402) MSA / Digital Diagnostic Monitoring
- Tx Power Rx Power Bias Current Case Temperature Power Supply Voltage
- QSFP28(SFF-8665), SFP28(SFF-8402) MSA / Distance
- 10 m
- QSFP28(SFF-8665), SFP28(SFF-8402) MSA / MSA compliance (SFF, for e.g. SFF-8665)
- QSFP28 MSA, SFF-8665, “QSFP28 28 Gb/s4X Pluggable Transceiver Solution (QSFP28)”, Rev 1.9, June 29, 2015 SFP28 MSA, SFF-8402, “Specification for SFP28 1X 28 Gb/s Pluggable Transceiver Solution (SFP28) ”, Rev 1.1, Sep 13, 2014
- QSFP28(SFF-8665), SFP28(SFF-8402) MSA / Maximum Power consumption (W)
- QSFP28 end: 3.5 W; SFP28 end: 1 W
- QSFP28(SFF-8665), SFP28(SFF-8402) MSA / Operating Temperature (range)
- 0° C to 70° C
- QSFP28(SFF-8665), SFP28(SFF-8402) MSA / Optic Type (Commercial Vs Service Provider Grade)
- OM3
- QSFP28(SFF-8665), SFP28(SFF-8402) MSA / Signaling rate, each lane
- 25.78125Gbd +/- 100ppm
- QSFP28(SFF-8665), SFP28(SFF-8402) MSA / Storage temperature
- –40° C to 85° C
- QSFP28(SFF-8665), SFP28(SFF-8402) MSA / Typical Weight & Dimensions
- Dimensions | QSFP28 | SFP28 Height | 8.5 mm | 8.5 mm Width | 18.35 mm | 13.4 mm Depth | 72.4 mm | 56.5 mm
- Documented selection limits
- Reach, rate, form factor and breakout support apply only to the listed standard/mode, fiber grade and platform/port configuration. Keep source qualifiers for FEC, attenuation, transmit/receive limits, temperature, active/passive operation and cable ends. Check Juniper HCT for the exact host, interface module, port mode, Junos release, required QSA adapter and qualifications before ordering. Do not infer universal interoperability or combine power/temperature/reach across model profiles. Optical link budgets are not calculated or inferred. Parallel fiber/core/modal-bandwidth/distance values retain the same source column order; correlate matching columns instead of applying the largest distance to every fiber.
- Integral-cable metadata note
- HCT Connector=None is integral DAC/AOC metadata, not an absence of cable ends. Verify end form factors and breakout against the exact manufacturer profile.
- Reading parallel values
- Pipe-separated fiber, bandwidth and reach values correspond by position in the original manufacturer column order. The longest reach does not apply to every fiber type.