Lenovo / Lenovo ThinkSystem storage adapters

Lenovo 4Y37A09724 · 440-16e

P/N: 4Y37A09724

HBALenovo ThinkSystem storage adapters

Storage HBA, not hardware RAID. Verify approved Lenovo server, backplane, cables and firmware; direct-attach and expander limits differ. Adapter type: HBA · Internal or External ports: External

Enquire ↗+998 77 161 11 11 ↗ +998 97 741 55 00 ↗
Photo pending verification
Photo pending verification
01 / Specifications
MPN / P/N
4Y37A09724
Manufacturer model
440-16e
Adapter type
HBA
Internal or External ports
External
Feature code
B8P7
Form factor
PCIe low profile
Controller chip
Broadcom SAS3816
Vendor equivalent
HBA 9500-16e
Host interface
PCIe 4.0 x8
Port interface
12 Gb SAS
Number of ports
16
Port connectors
4x Mini-SAS HD SFF8644
Drive interface
SAS/SATA
Drive type
HDD/SSD/SED (see Note 1)
Hot-swap drives
Yes
Max physical drives
1024
RAID levels
None
JBOD mode
Yes
Cache
None
Cache protection with Flash and Supercap
None
Performance Accelerator (FastPath)
No
SSD Caching (CacheCade Pro 2.0)
No
SED support (see Note 2)
Yes (see Note 1)
Remote management - Controller FW update (XCC/BMC) (see Note 5)
Yes
Remote management - Inventory (XCC/BMC) (see Note 5)
Yes
Documented selection limits
Use only the approved ThinkSystem server, slot/riser, backplane and correct cable/firmware configuration. Port count, direct physical-drive limit and expander-qualified drive limit are separate source fields. HBA passthrough is not hardware RAID. Flash/supercap support does not imply an optional module is supplied; consult the exact option guide. NVMe U.3 Tri-Mode x1 and NVMe-only U.2 x4 configurations are different and not simultaneous universal support; feature codes/CH5Z enablement and host cabling must be verified for RAID 940. Planned U.2 support stays planned, not a delivered feature. SED support on HBAs is host-software pass-through, not a bundled encryption/key-management service. Remote management exclusions and blade drive-count limits in sourceQualifications apply.
Manufacturer qualifications — required for selection
Note 1: RAID 730-8i 1GB is available world-wide except USA and Canada Note 2: SAS HBAs support SEDs by host software passing SED commands through the HBA to the drives. Note 3: SN550 blade 4i adapters are limited to two drives and RAID 0/1; SN850 has four drives and applicable RAID modes depend on the exact adapter. Note 5: SR635/SR655/SR645/SR665 with second-generation AMD EPYC (Rome) processors do not support remote management.

Specification source: Lenovo ↗
Checked against documentation: 19.10.2026