- MPN / P/N
- PWS-1K28P-SQ
- Manufacturer model
- Supermicro 1280W 1U Redundant Power Supply (PWS-1K28P-SQ)
- Brand
- Supermicro
- Total Power Output
- 1000W / 1280W
- Type of Power Supply
- Power Supply
- Form Factor
- 1U
- Dimension (W x H x L)
- 76 x 40 x 336mm
- +12V
- 83.3A/ 106.7A
- 5V Standby
- 4A
- Input Voltage Range
- 1000W: 100-140V; 1280W: 180-240V
- Input Frequency Range
- 50-60Hz
- Input Current Range
- 1000W: 12-8A; 1280W: 8-6A
- Output Type
- Gold Finger (23 Pair Connector)
- PFC
- Yes
- Energy Efficiency
- 95% Peak
- 80 Plus Certification
- 80 Plus Platinum
- Validated Systems
- AS-4023S-TRT, SSG-5048R-E1CR36L, SSG-6047R-E1CR36L, SSG-6047R-E1CR36N, SSG-6048R-E1CR36H, SSG-6048R-E1CR36L, SSG-6048R-E1CR36N, SYS-2027PR-DC0FR, SYS-2027PR-DC0R, SYS-2027PR-DC0TR, SYS-2027PR-DC1FR, SYS-2027PR-DC1R, SYS-2027PR-DC1TR, SYS-2027PR-DTFR, SYS-2027PR-DTR, SYS-2027PR-DTTR, SYS-2027TR-D70FRF, SYS-2027TR-D70QRF, SYS-2027TR-D70RF, SYS-2027TR-D70RF+, SYS-2028TP-DC0FR, SYS-2028TP-DC0R, SYS-2028TP-DC0TR, SYS-2028TP-DC1FR, SYS-2028TP-DC1R, SYS-2028TP-DC1TR, SYS-2028TP-DECFR, SYS-2028TP-DECR, SYS-2028TP-DECTR, SYS-2028TP-DTFR, SYS-2028TP-DTR, SYS-2028TP-DTTR, SYS-2028UT-BC1NRT, SYS-2028UT-BTNRT, SYS-6017TR-TF, SYS-6017TR-TFF, SYS-6017TR-TQF, SYS-6027AX-72RF, SYS-6027AX-72RF-HFT1, SYS-6027AX-72RF-HFT2, SYS-6027AX-72RF-HFT3, SYS-6027AX-TRF, SYS-6027AX-TRF-HFT1, SYS-6027AX-TRF-HFT2, SYS-6027AX-TRF-HFT3, SYS-6027TR-D70FRF, SYS-6027TR-D70QRF, SYS-6027TR-D70RF, SYS-6027TR-D70RF+, SYS-6027TR-D71FRF, SYS-6027TR-D71QRF, SYS-6027TR-D71RF, SYS-6027TR-D71RF+, SYS-6027TR-DTFRF, SYS-6027TR-DTQRF, SYS-6027TR-DTRF, SYS-6027TR-DTRF+, SYS-6028TR-D72R, SYS-6028TR-DTR, SYS-6037R-72RFT+, SYS-7047AX-72RF, SYS-7047AX-TRF, SYS-7047R-TXRF, SYS-7049P-TR, SYS-7049P-TRT, SYS-F628R2-FC0, SYS-F628R2-FC0+, SYS-F628R2-FC0PT+, SYS-F628R2-FT+, SYS-F628R2-FTPT+, SYS-F628R3-FC0, SYS-F628R3-FC0+, SYS-F628R3-FC0PT+, SYS-F628R3-FT, SYS-F628R3-FT+, SYS-F628R3-FTPT+, SYS-F628R3-R72B+, SYS-F628R3-R72BPT+, SYS-F628R3-RC0B+, SYS-F628R3-RC0BPT+, SYS-F628R3-RC1B+, SYS-F628R3-RC1BPT+, SYS-F628R3-RTB+, SYS-F628R3-RTBN+, SYS-F628R3-RTBPT+, SYS-F628R3-RTBPTN+
- Validated Chassis
- CSE-216BE16-R1K28LPB, CSE-216BE16-R1K28WB, CSE-216BE26-R1K28LPB, CSE-216BE26-R1K28WB, CSE-826BA-R1K28LPB, CSE-826BE16-R1K28LPB, CSE-826BE16-R1K28WB, CSE-826BE26-R1K28LPB, CSE-826BE26-R1K28WB, CSE-835BTQ-R1K28B, CSE-836BA-R1K28B, CSE-836BE16-R1K28B, CSE-836BE26-R1K28B, CSE-836BHA-R1K28B, CSE-836BHE16-R1K28B, CSE-836BHE26-R1K28B, CSE-846BE1C-R1K28B, CSE-846BE2C-R1K28B, CSE-846BE16-R1K28B, CSE-846BE26-R1K28B, CSE-847BA-R1K28LPB, CSE-847BE1C-R1K28LPB, CSE-847BE2C-R1K28LPB, CSE-847DE16-R1K28LPB, CSE-847E16-R1K28JBOD, CSE-847E16-R1K28LPB, CSE-847E16-R1K28WB, CSE-847E26-R1K28JBOD, CSE-847E26-R1K28LPB, CSE-847E26-R1K28WB
- Product Environmental Compliance
- RoHS and REACH compliant, details available upon request
- Documented selection limits
- Power rating depends on the exact AC/DC input range and configuration listed in the source. N+1/redundant capability does not mean every installation includes redundant modules. Verify approved chassis, connector/power distribution board, airflow direction, input voltage, cable and firmware/PMBus requirements.