Juniper / Juniper optical transceivers

Juniper QSFP-100G-DR · 740-088322

P/N: 740-088322

Optical TransceiverQSFP-100G-DR

Juniper optik modul yoki ulash kabeli. Platforma/Junos mosligi, tola, ulagich, uzunlik, breakout va FEC tekshiriladi. Masofa ko‘rsatilgan profilga tegishli, har qanday liniyaga emas. Liniya tezligi — hujjat bo‘yicha: 100 Gigabit Ethernet · Format: QSFP28 · Ulagich: Duplex LC PC/UPC · IEEE 100GBASE-DR / Masofa / uzunlik — profil shartlari bilan: 500 m

So‘rov ↗+998 77 161 11 11 ↗ +998 97 741 55 00 ↗
Juniper QSFP-100G-DR · 740-088322 — Xususiyatlar bo‘yicha sxema, fotosurat yoki o‘rnatish chizmasi emas.
Xususiyatlar bo‘yicha sxema, fotosurat yoki o‘rnatish chizmasi emas. Citadex Systems · Xususiyatlar manbasi
01 / Xususiyatlar
MPN / P/N
740-088322
Ishlab chiqaruvchi modeli
QSFP-100G-DR
Zavod raqami
740-088322
Liniya tezligi — hujjat bo‘yicha
100 Gigabit Ethernet
Breakout — platforma cheklovlari bilan
No
Format
QSFP28
Mahsulot turi
Optical Transceiver
Ulagich
Duplex LC PC/UPC
Monitoring mavjudligi
Yes
Raqamli optik monitoring
Yes
IEEE 100GBASE-DR / Kabel / tola turi
SMF
IEEE 100GBASE-DR / Yadro / qoplama o‘lchami
9/125 µm
IEEE 100GBASE-DR / Digital Diagnostic Monitoring
Transceiver Temperature Transceiver Supply Voltage Tx Bias Current Tx output power Rx received optical power
IEEE 100GBASE-DR / Masofa / uzunlik — profil shartlari bilan
500 m
IEEE 100GBASE-DR / Tola sinfi
IEEE Clause 140.10.1: IEC 60793-2-50 type B1.1, type B1.3, or type B6_a or requirements in IEEE Table 140–13 where they differ.
IEEE 100GBASE-DR / MSA compliance (SFF, for e.g. SFF-8665)
SFF-8665
IEEE 100GBASE-DR / Maksimal quvvat sarfi
4.0 W
IEEE 100GBASE-DR / Ishlash harorati oralig‘i
0° C to 70° C
IEEE 100GBASE-DR / Qabul kanali to‘lqin uzunligi oralig‘i
1304.5 nm to 1317.5 nm
IEEE 100GBASE-DR / Har kanal maksimal kirish quvvati
4 dBm
IEEE 100GBASE-DR / Har kanal minimal kirish quvvati
-5.9 dBm
IEEE 100GBASE-DR / Receiver sensitivity (OMA), each lane (maximum)
max (−3.9,SECQ -5.3) dBm
IEEE 100GBASE-DR / Har bir kanal signal tezligi
Host lane: NRZ; 25.78125 GBd ± 100 ppm Media lane: PAM4; 53.125 GBd ± 100 ppm
IEEE 100GBASE-DR / Saqlash harorati
–40° C to 85° C
IEEE 100GBASE-DR / Stressed receiver sensitivity (OMA) each lane (maximum)
-1.9 dBm
IEEE 100GBASE-DR / Qo‘llanadigan breakout sxemalari
100GBASE-DR (clause 140), CAUI-4 (no FEC)
IEEE 100GBASE-DR / Transmitter and dispersion eye closure for PAM4 (TDECQ), each lane (maximum)
3.4 dB
IEEE 100GBASE-DR / Transmitter fibers
1
IEEE 100GBASE-DR / Har kanal maksimal chiqish quvvati
4 dBm
IEEE 100GBASE-DR / Har kanal minimal chiqish quvvati
-2.9 dBm
IEEE 100GBASE-DR / Uzatgich to‘lqin uzunligi oralig‘i
1304.5 nm to 1317.5 nm
IEEE 100GBASE-DR / Typical Weight & Dimensions
Weight: 0.2 kg Height: 13.5 mm Width: 18.35 mm Depth: 73.4 mm
Hujjatdagi tanlash cheklovlari
Reach, rate, form factor and breakout support apply only to the listed standard/mode, fiber grade and platform/port configuration. Keep source qualifiers for FEC, attenuation, transmit/receive limits, temperature, active/passive operation and cable ends. Check Juniper HCT for the exact host, interface module, port mode, Junos release, required QSA adapter and qualifications before ordering. Do not infer universal interoperability or combine power/temperature/reach across model profiles. Optical link budgets are not calculated or inferred. The source explicitly distinguishes these single-wavelength optics from earlier 100G CWDM4/LR4 optics: do not assume interoperability; supported mixed links use the shortest applicable reach.
HCT moslik va masofa shartlari
QSFP-100G-DR bir to‘lqinli DR↔DR/FR va tasdiqlangan 400G DR4↔4×100G DR breakout ulanishlarini qo‘llaydi. Juftlikning qisqaroq masofasi olinadi. Eski CWDM4/LR4 bilan mos deb olinmaydi.

Xususiyatlar manbasi: Juniper ↗
Hujjat bo‘yicha tekshirildi: 19.10.2026

Katalog taklif so‘rash uchun ma’lumotnoma hisoblanadi. Mavjudlik, ishlab chiqarish holati, uskunaning holati, narx, muddat va kafolat alohida tasdiqlanadi. Artikul ro‘yxatda borligi omborda borligini anglatmaydi.