- MPN / P/N
- 740-088322
- Ishlab chiqaruvchi modeli
- QSFP-100G-DR
- Zavod raqami
- 740-088322
- Liniya tezligi — hujjat bo‘yicha
- 100 Gigabit Ethernet
- Breakout — platforma cheklovlari bilan
- No
- Format
- QSFP28
- Mahsulot turi
- Optical Transceiver
- Ulagich
- Duplex LC PC/UPC
- Monitoring mavjudligi
- Yes
- Raqamli optik monitoring
- Yes
- IEEE 100GBASE-DR / Kabel / tola turi
- SMF
- IEEE 100GBASE-DR / Yadro / qoplama o‘lchami
- 9/125 µm
- IEEE 100GBASE-DR / Digital Diagnostic Monitoring
- Transceiver Temperature Transceiver Supply Voltage Tx Bias Current Tx output power Rx received optical power
- IEEE 100GBASE-DR / Masofa / uzunlik — profil shartlari bilan
- 500 m
- IEEE 100GBASE-DR / Tola sinfi
- IEEE Clause 140.10.1: IEC 60793-2-50 type B1.1, type B1.3, or type B6_a or requirements in IEEE Table 140–13 where they differ.
- IEEE 100GBASE-DR / MSA compliance (SFF, for e.g. SFF-8665)
- SFF-8665
- IEEE 100GBASE-DR / Maksimal quvvat sarfi
- 4.0 W
- IEEE 100GBASE-DR / Ishlash harorati oralig‘i
- 0° C to 70° C
- IEEE 100GBASE-DR / Qabul kanali to‘lqin uzunligi oralig‘i
- 1304.5 nm to 1317.5 nm
- IEEE 100GBASE-DR / Har kanal maksimal kirish quvvati
- 4 dBm
- IEEE 100GBASE-DR / Har kanal minimal kirish quvvati
- -5.9 dBm
- IEEE 100GBASE-DR / Receiver sensitivity (OMA), each lane (maximum)
- max (−3.9,SECQ -5.3) dBm
- IEEE 100GBASE-DR / Har bir kanal signal tezligi
- Host lane: NRZ; 25.78125 GBd ± 100 ppm Media lane: PAM4; 53.125 GBd ± 100 ppm
- IEEE 100GBASE-DR / Saqlash harorati
- –40° C to 85° C
- IEEE 100GBASE-DR / Stressed receiver sensitivity (OMA) each lane (maximum)
- -1.9 dBm
- IEEE 100GBASE-DR / Qo‘llanadigan breakout sxemalari
- 100GBASE-DR (clause 140), CAUI-4 (no FEC)
- IEEE 100GBASE-DR / Transmitter and dispersion eye closure for PAM4 (TDECQ), each lane (maximum)
- 3.4 dB
- IEEE 100GBASE-DR / Transmitter fibers
- 1
- IEEE 100GBASE-DR / Har kanal maksimal chiqish quvvati
- 4 dBm
- IEEE 100GBASE-DR / Har kanal minimal chiqish quvvati
- -2.9 dBm
- IEEE 100GBASE-DR / Uzatgich to‘lqin uzunligi oralig‘i
- 1304.5 nm to 1317.5 nm
- IEEE 100GBASE-DR / Typical Weight & Dimensions
- Weight: 0.2 kg Height: 13.5 mm Width: 18.35 mm Depth: 73.4 mm
- Hujjatdagi tanlash cheklovlari
- Reach, rate, form factor and breakout support apply only to the listed standard/mode, fiber grade and platform/port configuration. Keep source qualifiers for FEC, attenuation, transmit/receive limits, temperature, active/passive operation and cable ends. Check Juniper HCT for the exact host, interface module, port mode, Junos release, required QSA adapter and qualifications before ordering. Do not infer universal interoperability or combine power/temperature/reach across model profiles. Optical link budgets are not calculated or inferred. The source explicitly distinguishes these single-wavelength optics from earlier 100G CWDM4/LR4 optics: do not assume interoperability; supported mixed links use the shortest applicable reach.
- HCT moslik va masofa shartlari
- QSFP-100G-DR bir to‘lqinli DR↔DR/FR va tasdiqlangan 400G DR4↔4×100G DR breakout ulanishlarini qo‘llaydi. Juftlikning qisqaroq masofasi olinadi. Eski CWDM4/LR4 bilan mos deb olinmaydi.